Code: 61🚿 Rheem Tankless Water Heater

Rheem Tankless Water Heater Code 61: Blower Fan Speed Problem (Meaning, Causes, Fixes)

Reviewed 2026-10-23 · Based on 6 manufacturer & service sources

What the code means

Rheem's High Efficiency Tankless Water Heater with Recirculation Troubleshooting Manual (AP24838) calls 61 "Blower motor speed incorrect for combustion": the heater checks the fan's RPM signal after the fan starts, and if that signal is wrong it shows 61. Rheem's SVC 820 pocket troubleshooting manual words it as "The Blower motor speed was not appropriate to allow proper combustion." The older SVC 810 training manual calls it "Combustion Fan Failure" (fan motor does not work properly), and Rheem's tankless Use and Care Manual lists "61 or 99" as "Faulty blower motor. Contact a dealer or qualified service technician." Rheem Australia's continuous-flow list gives the same idea: abnormal fan speed or fan failure.

Likely causes

Safe DIY checks

⚠ Before you start

Unplug the appliance (or switch off its breaker) and shut off the water supply valves before removing panels or disconnecting hoses. Keep towels handy for residual water.

  1. Do Rheem's reset: turn off all hot water faucets, turn the heater off with the POWER ON/OFF button, wait about 5 minutes, turn it back on, then open a hot faucet and check the display. If the code is still there, turn the faucet and heater off, unplug the heater for 30 seconds, plug it back in and repeat.
  2. Go outside (or to the vent terminations) and check that the air intake and exhaust aren't blocked by snow, leaves, nests, lint or anything stacked against them. Clear anything you find.
  3. If the heater was recently installed or the vent was changed, ask the installer to confirm the vent run is within the maximum length and number of elbows in your model's manual; Rheem's older service manual lists over-length venting as a code 61 check.
  4. While hot water is running, you can feel for airflow at the exhaust termination; Rheem's service manual asks technicians to confirm some air is coming out of the flue.
  5. Don't open the heater's cover or probe the fan connector. Rheem's own procedure involves live DC voltages up to about 195 volts at the blower connector and warns that touching the wrong two wires can damage the blower motor and control board, so leave it to a technician if the reset doesn't clear 61.

🛠 When to call a pro

  • Turning power off, removing and reinserting the blower connector at the control board and at the motor, then running the unit again (Rheem says if 61 doesn't return, it was a loose connection).
  • Removing the blower motor, cleaning the motor and its housing, checking it turns freely, and reassembling.
  • Measuring the blower motor's supply, control and speed-signal voltages at the control board connector per the model's troubleshooting manual (for example, about 145 to 195 DC volts supply, 12 to 18 DC volts control and a 4 to 10 DC volt pulsing speed signal on the AP24838 models), using Rheem's warning about which wire pairs never to bridge.
  • Replacing the control board or blower motor according to which reading fails, then checking gas supply and venting if both test good.
  • Inspecting the fan motor wiring harness for damaged or loose terminals and checking venting length and bends against the installation manual.

Parts that commonly fix it

Always match the part number to your exact model.

⚙

Plug-in carbon monoxide alarm with digital display

Worth having near any gas water heater, especially when venting or combustion airflow is in question.

[affiliate link slot: AFFILIATE_SLOT_CO_DETECTOR]
⚙

Rheem tankless blower motor (exact part for your model)

Technician part only, after testing shows the motor has failed.

[affiliate link slot: AFFILIATE_SLOT_BLOWER_MOTOR]
⚙

Rheem tankless control board (exact part for your model)

Technician part only, after testing points to the board.

[affiliate link slot: AFFILIATE_SLOT_BOARD]

Sources

  1. Rheem High Efficiency Tankless Water Heater with Recirculation Troubleshooting Manual AP24838 (61: blower motor speed incorrect for combustion; RPM signal check, reseat connectors, voltage checks, replace board or blower)
  2. Rheem Tankless Gas Troubleshooting Pocket Manual SVC 820 (P) (61: blower speed not appropriate for proper combustion; clean blower and housing; connector G voltage checks)
  3. Rheem/Ruud Tankless Training Manual SVC 810, 2nd Edition (61: combustion fan failure; fan turns freely, air from flue, harness, venting length and bends)
  4. Rheem Tankless Water Heater Use and Care Manual (61 or 99: faulty blower motor, contact a dealer or qualified technician)
  5. Rheem Tankless Easy Installation Guide (clearing-alarms reset steps)
  6. Rheem Australia hot water troubleshooting guide (61: abnormal fan speed or fan failure)

Last reviewed 2026-10-23. Always confirm against the manual for your exact model number.