Code: E4๐Ÿ”ง York Mini Split

York Mini Split Error Code E4: High Discharge Temperature Protection (Meaning, Causes, Fixes)

Reviewed 2026-10-25 ยท Based on 2 manufacturer & service sources

What the code means

York (Johnson Controls) uses E4 for compressor discharge temperature protection on its ductless mini splits. The M series multi-zone service manual (outdoor models DHM18CMB21S through DHM42CMB21S, on yorknow.com) lists E4 as High Discharge Temp Protection, an outdoor-unit error shown on the indoor display and the outdoor unit's display, with the indicator flashing 4 times. Its control description says that as discharge temperature rises the compressor first limits or lowers its speed, and when it gets too high the compressor stops; if discharge temperature protection happens 6 times in a row, the compressor can't resume until the power is cut off and switched back on (the count clears once the compressor runs longer than 7 minutes). Its E4 flowchart checks whether the discharge temperature has actually reached 115 C (239 F). The York P series 9K-12K 115 V single-zone service manual also lists E4 as Compressor exhaust high temperature protection, with 4 blinks on the indoor lamp. Related codes on the same units: F5 is a failed (open or shorted) exhaust temperature sensor, F9 on the P series is the earlier high exhaust temperature speed limit, E1 is high pressure protection and E3 is low pressure protection.

Likely causes

Safe DIY checks

โš  Before you start

The outdoor unit has line voltage and an inverter board that can stay charged after power is removed (York's P series procedure waits 20 minutes), and the compressor's discharge line can be hot enough to burn. Shut off power at the disconnect before cleaning the outdoor unit, keep the electrical covers on and leave sensor, valve and refrigerant work to a licensed technician.

  1. Turn the system off with the remote. On M series multi-zone units, if it has locked out after repeated trips, switch the outdoor unit's breaker or disconnect off for a few minutes and back on.
  2. Clean or replace the indoor unit's filters and make sure the indoor unit's air intake and outlet aren't blocked.
  3. With power off at the outdoor disconnect, clear leaves, grass or stored items from around the outdoor unit and gently rinse a dirty outdoor coil with a garden hose (no pressure washer).
  4. Look for oily spots on the refrigerant line connections at the indoor and outdoor units, which can point to a leak. Don't loosen any fittings yourself.
  5. If E4 comes back, stop resetting it and call a technician. Running a compressor that keeps overheating can damage it.

๐Ÿ›  When to call a pro

  • A technician measures the actual compressor discharge temperature. York's M series flowchart uses 115 C (239 F) as the line: at or above it, the system has a leak and needs repair and recharge to the nameplate amount.
  • If the discharge temperature isn't really that high, the discharge temperature sensor's resistance is checked against York's resistance table and the sensor is replaced if it's off; if the sensor is fine, the outdoor mainboard is replaced.
  • On P series units, York's diagnosis has the technician wait 20 minutes after powering off, then check the electronic expansion valve's connection and coil resistance (the first four pins to the fifth should be about equal and under 100 ohms), replace the valve or the outdoor control board, and then look for a refrigerant leak.
  • Leak repair and recharging must be done by an EPA-certified technician.

Parts that commonly fix it

Always match the part number to your exact model.

โš™

Refrigerant leak detector

For a technician tracking down the leak York's E4 flowchart points to.

Search eBay โ†’
โš™

Coil cleaner

For cleaning a dirty outdoor coil with the power off.

Search eBay โ†’
โš™

Multimeter

For checking the discharge temperature sensor's resistance against York's table.

Search eBay โ†’

Sources

  1. York (Johnson Controls) M series inverter multi-zone service manual, DHM18CMB21S-DHM42CMB21S (E4 High Discharge Temp Protection error table, 2.3 discharge protection function with 6-time lockout and power reset, E4 troubleshooting flowchart at 115 C, Appendix 3 discharge sensor resistance table)
  2. York P series 9K-12K 115 V inverter mini split service manual, 7.2 error code list (E4 Compressor exhaust high temperature protection, F5 exhaust sensor, F9 high exhaust temperature limit), discharge temperature protection logic and overload/exhaust malfunction diagnosis

Last reviewed 2026-10-25. Always confirm against the manual for your exact model number.