Goodman Furnace EA5 (EAS) Code: R-32 Refrigerant Sensor Fault (Meaning, Fixes)

Reviewed 2026-10-23 ยท Based on 4 manufacturer & service sources

What the code means

Goodman's R-32-ready gas furnaces (for example the GR9S96, GD9S96 and GR9S92 families) have a control board that watches a refrigerant leak sensor mounted on the indoor evaporator coil, so it can shut off the gas and run the blower if R-32 leaks. The wiring-diagram status table lists four A2L (mildly flammable refrigerant) alarms: EAF for lost communication with the sensor, EAL for a detected refrigerant leak, EAS for an A2L internal alarm, and EAr for a fault in the board's A2L relay. Goodman's troubleshooting chart describes EAS as "R-32 sensor has detected a fault and the furnace is in mitigation mode," with the symptom that the furnace stops heating and only the fan operates. So EAS isn't a leak reading and isn't a lost connection: the board is still talking to the sensor, and the sensor itself is reporting that something is wrong with it. Goodman doesn't publish an EA5 code; the display uses a lowercase-style S that reads as 5, which is why so many people search for EA5.

Likely causes

Safe DIY checks

โš  Before you start

Turn off power at the furnace/HVAC service switch and the breaker before opening panels. Shut the gas valve before any work near the burners, and never disconnect or alter the gas line. If you smell gas, leave the house and call your gas utility.

  1. Read the display carefully and write down exactly what it shows. EA5 on a Goodman furnace is the EAS code; if it reads EAL instead, the sensor thinks it smells refrigerant, so treat it as a possible leak and call a technician.
  2. Leave the blower running. In mitigation mode the furnace runs the fan on purpose to clear any refrigerant from the coil area, and it won't heat until the fault clears.
  3. Turn the furnace off at its service switch or breaker for about a minute, then back on. At startup the board looks for the sensor again; a green LED next to the sensor connection on the control board stays on during startup, then blinks if the sensor is talking to the board or goes off if there's no signal.
  4. With the power off, look at the sensor wire where it runs from the indoor coil into the furnace blower compartment and plugs into the control board. Make sure it's plugged in firmly and isn't crushed, cut or touching anything hot.
  5. To see past codes, press the left or right button until the display shows L6F (printed "L 6 F" in the manual), then press the center button to view stored faults. Goodman says pressing and holding the center button for 5 to 30 seconds erases them; the display flashes three dashes when it's done.

๐Ÿ›  When to call a pro

  • EAS comes back after a power cycle. Goodman's corrective action is to investigate the R-32 sensor and replace it, which means working on the indoor coil.
  • Replacing the R-32 refrigerant sensor with the exact part for your coil and furnace. The sensor is matched to the A2L system, so it isn't a generic part.
  • Any doubt about whether the system actually uses R-32. Goodman says the R-32 function must stay on for furnaces paired with an R-32 outdoor unit and should only be turned off in the A2E menu for R-410A systems or furnace-only installs, so a tech should confirm which you have before changing it.
  • Checking for a real refrigerant leak if the code ever changes to EAL, or if the cooling isn't working well.
  • You smell gas or a carbon monoxide alarm sounds. Leave the house and call your gas utility from outside.

Parts that commonly fix it

Always match the part number to your exact model.

โš™

Digital multimeter

For the tech-level wiring checks; not needed for the basic reset.

Search eBay โ†’

Sources

  1. Goodman *R9S96/*D9S96 & *R9S92 installation instructions IOG-2037B (troubleshooting chart: EAS = R-32 sensor has detected a fault, furnace in mitigation mode, investigate and replace the R-32 sensor; EAF, EAL and EAr rows; R-32 Information: function ON by default, A2E menu, sensor wire routing, green LED at startup; view and clear fault codes)
  2. Goodman GR9S96-U wiring diagram status and fault table (A2L communication alarm EAF, A2L leakage alarm EAL, A2L internal alarm EAS, A2L relay alarm EAr; A2L mode enabled by default)
  3. Daikin Technical Service Bulletin TSB C-GN-OT-0077 (R-32 function ON by factory default; disable only for R-410A or furnace-only installs; never disable when paired with an R-32 outdoor unit)
  4. Johnstone Supply support: Goodman A2L Functionality, A2E and A2U Information (mitigation mode, cycle power after changing A2E, startup LED behavior)

Last reviewed 2026-10-23. Always confirm against the manual for your exact model number.